National Repository of Grey Literature 6 records found  Search took 0.00 seconds. 
Contact erosion of switchgear under real conditions
Holoubek, Josef ; Bušov, Bohuslav (referee) ; Valenta, Jiří (advisor)
This bachelor thesis is focused on the material loss - contacts erosion during switching process of the switchgears. First part is focused on the switchgears generally, their dividing and functions. Then there is closer look on the contacts of switchgears and what is necessary to be considered during their designing a operating. In this part there is also section devoted to the theory of the contacts erosion including the formulas for material loss calculation, which I found in existing literature. Practical part is focused on the contact system model and the measuring performed on this model. Measuring was also performed on the real switchgears for common use. There is also part devoted to this measuring. In the last part of thesis the analyze of the measured values is performed.
Integration of Photovoltaic Power Plants in the Electricity System
Michl, Pavel ; Paar, Martin (referee) ; Mastný, Petr (advisor)
The thesis discuses an integration of photovoltaic power stations to electric network. The first part describes connecting conditions of small sources to distribution system, including administrative requirements, feasibility study, and requirements to the energy meters, measuring, control devices, switching devices and protection. The second part is aimed to describe problems of the photovoltaic system. Solar radiation generating and reducing of its intensity incident upon the earth surface are described in this part. The quantum of produced electric power depends on climatic conditions in the fixed area, seasons, etc. This work also discusses the types of photovoltaic cells and their actual efficiency. Inverters are further important components of the photovoltaic system. The parameters of the inverters have a great influence on the total actual efficiency of the photovoltaic system. Different methods of the photovoltaic panels’ connection with the inverters and their advantages and disadvantages are also mentioned. The supporting structure of the photovoltaic panels and eventually transformer are further important components of photovoltaic system. The work also analyze the methods of connection of the photovoltaic power station to distributive low voltage and medium voltage network, electric energy accumulation and possibilities of the sale of produced electric energy. The large number of the connected photovoltaic power stations has negative influences to electric network. The third part contains the design of a photovoltaic power plant with a capacity of 516,24 kWp on the scoped area in southern Bohemia. The project documentation for the location where the power plant is designed is also made. It contains the design of photovoltaic panels, the design of the inverters to get an optimal power load. This part also contains a calculation of the photovoltaic system losses and the design of transformer and the cable junction calculation of the distributive system. The feasibility study of the power plant connected to distributive system is also conducted. Its delivery rate will be connected to the distribution point Řípov (110/22 kV). The calculation results show us that this photovoltaic power plant can be linked to the distribution system. The final part of this paper contains an economic estimate of the photovoltaic power plant operating and the calculation of the return. An Economic return is influenced by the wide range of values that affect the total return rate. The calculation of an operating economy is made for several variants. The return rate in refer to contemporary redemption price for 2010 with no consideration for a bank loan is 7 years. If we consider the bank loan it would be 12 years. The penetrative reduction of the redemption price is expected for 2011. Calculation works with the decline of 30 %. It would extend the rate of return to 11 years without a bank loan or to 22 years with the bank loan. The bank loan is considered to cover 80 % of the investment.
Contact erosion of switching devices
Píška, Jakub ; Šimek, David (referee) ; Valenta, Jiří (advisor)
This bachelor thesis deals with the erosion of contacts, as one of the negative phenomena affecting contacts of switchgears. In its first part, it briefly summarizes the other negative influences that must be considered when designing switching devices. In the following part, the physical mechanism of erosion and the primary criterion of assessment - weight loss are approached. The last and main part of the work deals with design of the contact system for comparing this loss for for frequently used materials and testing on a real switchgear. After the tests, the results were analyzed primarily from the perspective of ignition angles, the polarities of the current pulse and the current flowing through the arc. Taking into account the influence of the material composition, the size of the contacts and the presence of the arc-runner.
Contact erosion of switching devices
Píška, Jakub ; Šimek, David (referee) ; Valenta, Jiří (advisor)
This bachelor thesis deals with the erosion of contacts, as one of the negative phenomena affecting contacts of switchgears. In its first part, it briefly summarizes the other negative influences that must be considered when designing switching devices. In the following part, the physical mechanism of erosion and the primary criterion of assessment - weight loss are approached. The last and main part of the work deals with design of the contact system for comparing this loss for for frequently used materials and testing on a real switchgear. After the tests, the results were analyzed primarily from the perspective of ignition angles, the polarities of the current pulse and the current flowing through the arc. Taking into account the influence of the material composition, the size of the contacts and the presence of the arc-runner.
Contact erosion of switchgear under real conditions
Holoubek, Josef ; Bušov, Bohuslav (referee) ; Valenta, Jiří (advisor)
This bachelor thesis is focused on the material loss - contacts erosion during switching process of the switchgears. First part is focused on the switchgears generally, their dividing and functions. Then there is closer look on the contacts of switchgears and what is necessary to be considered during their designing a operating. In this part there is also section devoted to the theory of the contacts erosion including the formulas for material loss calculation, which I found in existing literature. Practical part is focused on the contact system model and the measuring performed on this model. Measuring was also performed on the real switchgears for common use. There is also part devoted to this measuring. In the last part of thesis the analyze of the measured values is performed.
Integration of Photovoltaic Power Plants in the Electricity System
Michl, Pavel ; Paar, Martin (referee) ; Mastný, Petr (advisor)
The thesis discuses an integration of photovoltaic power stations to electric network. The first part describes connecting conditions of small sources to distribution system, including administrative requirements, feasibility study, and requirements to the energy meters, measuring, control devices, switching devices and protection. The second part is aimed to describe problems of the photovoltaic system. Solar radiation generating and reducing of its intensity incident upon the earth surface are described in this part. The quantum of produced electric power depends on climatic conditions in the fixed area, seasons, etc. This work also discusses the types of photovoltaic cells and their actual efficiency. Inverters are further important components of the photovoltaic system. The parameters of the inverters have a great influence on the total actual efficiency of the photovoltaic system. Different methods of the photovoltaic panels’ connection with the inverters and their advantages and disadvantages are also mentioned. The supporting structure of the photovoltaic panels and eventually transformer are further important components of photovoltaic system. The work also analyze the methods of connection of the photovoltaic power station to distributive low voltage and medium voltage network, electric energy accumulation and possibilities of the sale of produced electric energy. The large number of the connected photovoltaic power stations has negative influences to electric network. The third part contains the design of a photovoltaic power plant with a capacity of 516,24 kWp on the scoped area in southern Bohemia. The project documentation for the location where the power plant is designed is also made. It contains the design of photovoltaic panels, the design of the inverters to get an optimal power load. This part also contains a calculation of the photovoltaic system losses and the design of transformer and the cable junction calculation of the distributive system. The feasibility study of the power plant connected to distributive system is also conducted. Its delivery rate will be connected to the distribution point Řípov (110/22 kV). The calculation results show us that this photovoltaic power plant can be linked to the distribution system. The final part of this paper contains an economic estimate of the photovoltaic power plant operating and the calculation of the return. An Economic return is influenced by the wide range of values that affect the total return rate. The calculation of an operating economy is made for several variants. The return rate in refer to contemporary redemption price for 2010 with no consideration for a bank loan is 7 years. If we consider the bank loan it would be 12 years. The penetrative reduction of the redemption price is expected for 2011. Calculation works with the decline of 30 %. It would extend the rate of return to 11 years without a bank loan or to 22 years with the bank loan. The bank loan is considered to cover 80 % of the investment.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.